FAQ No. FAQ02003
Question
Can the pushbutton switches be used with a microload?
Answer
Yes. Some of the Pushbutton Switches can be used.
Applicable models (minimum application load)
1) A16 Series Pushbutton Switch: DC5V1mA
(exception: A165E-[]-[]-01/02: DC5V160mA)
2) All A3D Series: DC5V1mA
3) All A3C Series: DC5V1mA
4) A22 Switch Unit for minimum load: DC5V1mA

5) A3P Minimum Load Series: C5V1mA

6) A3K Minimum Load Series: DC5V1mA

Contact faults may occur if a switch for general loads is used for opening
and closing microloads.
Refer to the diagram below and select the appropriate switch for the range
of load used.
Even when Microload Switches are used within the range indicated in the
diagram, if inrush current occurs at switching, it may cause heavy contact
wear and shorten the life of the Switch. Use a contact protection circuit
when necessary.

Other Pushbutton / Indicator Lamp
FAQs
What is an enabling switch?
Are there water-resistant pushbutton switches?
What is incandescent illumination?
|