Safety Sensor Topic: Light-ON Outputs as Default Control Output

 

FAQ No. FAQ02330

 

Question

 

What is the difference between F3SN / F3SH Safety Light Curtains and F3W Area Sensors?

 

 

Answer

F3SN / F3SH series Safety Light Curtainsconform to safety system construction for any category but other Line Sensors F3W-series, F3WN-series, and F3ZN-series for workpiece detection cannot be used in constructing safety systems.


In practical terms, the safety of systems is ensured with F3SN/F3SH series mainly because these products have the following four functions.


F3W-series and F3WN-series, on the other hand, do not have the design features listed under 1 to 4 below, so they cannot be used in safety applications.

Main Functions of F3SN/F3SH Series

1. The Sensor itself regularly performs diagnostic checks.


Self tests for F3SN/F3SH Series
Self diagnosis functions for F3SS-AT60P
 


2. The Sensor itself detects external malfunction factors (e.g., noise and external light interference) in addition to malfunctions.
 


3. The Sensor has a failsafe design to always ensure a safe status (control outputs OFF) even if the Sensor is malfunctioning.

 


4. The control outputs always use light-ON operation.


(Note: On the other hand, the potentially dangerous option of dark-ON can be selected for F3W-series, F3WN-series, and F3ZN-series.)



 

Other Safety Sensor FAQs

 What is the self-diagnostic function?

 What is the protective height?

 What is the smallest detectable object for the F3SN?