FAQ No. FAQ02413
Question
What is an auxiliary output?
Answer
The default setting of the output is the reverse signal of the
control output. It is only an auxiliary output, so do not use it as a
control output for a safety circuit.
For F3SN-A and
F3SH Series, the output operation mode can be selected
using Setting Console F39-MC11.
Dark-ON output = Control output and its
reverse signal (default setting)
Light-ON output = Synchronized with the
control output
Light diagnosis output
Lockout output
Outermost-beam monitoring output
Specified-beam output
Blanking monitoring output (F3SN-A only)
F3SL Series Safety Light Curtains
A signal is output in sync with the control output. It is only an
auxiliary output, so do not use it as a control output for a safety
circuit.