Safety Sensor Topic: Auxiliary Output

 

FAQ No. FAQ02413

 

Question

 

What is an auxiliary output?


 

Answer


The default setting of the output is the reverse signal of the control output. It is only an auxiliary output, so do not use it as a control output for a safety circuit.


For F3SN-A and F3SH Series, the output operation mode can be selected using Setting Console F39-MC11.

  • Dark-ON output = Control output and its reverse signal (default setting)

  • Light-ON output = Synchronized with the control output

  • Light diagnosis output

  • Lockout output

  • Outermost-beam monitoring output

  • Specified-beam output

  • Blanking monitoring output (F3SN-A only)

F3SL Series Safety Light Curtains

A signal is output in sync with the control output. It is only an auxiliary output, so do not use it as a control output for a safety circuit.

 

Other Safety Sensor FAQs

 What is a manual reset?