Measuring and Monitoring Relays
            
        
* Information in this page is a reference that you created on the basis of information in the product catalog before the end of production, may be different from the current situation, such as goods for / supported standards options / price / features of the product. Before using, please check the compatibility and safety system.
last update: October 11, 2012
| Single-phase Current Relay | Measuring current | Supply voltage | Model | 
|---|---|---|---|
										 
										 | 
									2 to 20 mA AC/DC, 10 to 100 mA AC/DC, 50 to 500 mA AC/DC  | 
									24 VAC/DC | K8AB-AS1 24 VAC/DC | 
| 100-115 VAC | K8AB-AS1 100-115 VAC | ||
| 200-230 VAC | K8AB-AS1 200-230 VAC | ||
| 0.1 to 1 A AC/DC, 0.5 to 5 A AC/DC, 0.8 to 8 A AC/DC  | 
									24 VAC/DC | K8AB-AS2 24 VAC/DC | |
| 100-115 VAC | K8AB-AS2 100-115 VAC | ||
| 200-230 VAC | K8AB-AS2 200-230 VAC | ||
| 10 to 100 A AC, 20 to 200 A AC (See note.)  | 
									24 VAC/DC | K8AB-AS3 24 VAC/DC | |
| 100-115 VAC | K8AB-AS3 100-115 VAC | ||
| 200-230 VAC | K8AB-AS3 200-230 VAC | 
| Current Transformer | Input range | Applicable Relay | Model | 
|---|---|---|---|
										 
										 | 
									10 to 100 A AC, 20 to 200 A AC  | 
									K8AB-AS3 | K8AC-CT200L | 
| CT current on secondary side | Applicable Relay | 
|---|---|
| 0 to 1 A AC, 0 to 5 A AC  | 
									K8AB-AS2 | 
| Single-phase Voltage Relay | Measuring voltage | Supply voltage | Model | 
|---|---|---|---|
										 
										 | 
									6 to 60 mV AC/DC, 10 to 100 mV AC/DC, 30 to 300 mV AC/DC  | 
									24 VAC/DC | K8AB-VS1 24 VAC/DC | 
| 100-115 VAC | K8AB-VS1 100-115 VAC | ||
| 200-230 VAC | K8AB-VS1 200-230 VAC | ||
| 1 to 10 V AC/DC, 3 to 30 V AC/DC, 15 to 150 V AC/DC  | 
									24 VAC/DC | K8AB-VS2 24 VAC/DC | |
| 100-115 VAC | K8AB-VS2 100-115 VAC | ||
| 200-230 VAC | K8AB-VS2 200-230 VAC | ||
| 20 to 200 V AC/DC, 30 to 300 V AC/DC, 60 to 600 V AC/DC  | 
									24 VAC/DC | K8AB-VS3 24 VAC/DC | |
| 100-115 VAC | K8AB-VS3 100-115 VAC | ||
| 200-230 VAC | K8AB-VS3 200-230 VAC | 
            A shunt is a resistor to convert a DC current into a DC voltage.
Use the shunt in combination with K8AB-VS to detect undercurrent and overcurrent in DC circuits.
        
| Model | Rated current | Output voltage | 
|---|---|---|
| SDV-SH5 | 5 A | 60 mV | 
| SDV-SH7.5 | 7.5 A | |
| 7.5 A (for 100 mV) | 100 mV | |
| SDV-SH10 | 10 A | 60 mV | 
| SDV-SH15 | 15 A | |
| SDV-SH20 | 20 A | |
| SDV-SH30 | 30 A | |
| SDV-SH50 | 50 A | |
| SDV-SH75 | 75 A | |
| SDV-SH100 | 100 A | |
| SDV-SH150 | 150 A | |
| SDV-SH200 | 200 A | |
| SDV-SH300 | 300 A | |
| SDV-SH500 | 500 A | |
| SDV-SH750 | 750 A | |
| SDV-SH1000 | 1,000 A | 
       
    
| Single-phase Voltage Relay | Measuring voltage | Supply voltage | Model | 
|---|---|---|---|
										 
										 | 
									6 to 60 mV AC/DC, 10 to 100 mV AC/DC, 30 to 300 mV AC/DC  | 
									24 VAC/DC | K8AB-VW1 24 VAC/DC | 
| 100-115 VAC | K8AB-VW1 100-115 VAC | ||
| 200-230 VAC | K8AB-VW1 200-230 VAC | ||
| 1 to 10 V AC/DC, 3 to 30 V AC/DC, 15 to 150 V AC/DC  | 
									24 VAC/DC | K8AB-VW2 24 VAC/DC | |
| 100-115 VAC | K8AB-VW2 100-115 VAC | ||
| 200-230 VAC | K8AB-VW2 200-230 VAC | ||
| 20 to 200 V AC/DC, 30 to 300 V AC/DC, 60 to 600 V AC/DC  | 
									24 VAC/DC | K8AB-VW3 24 VAC/DC | |
| 100-115 VAC | K8AB-VW3 100-115 VAC | ||
| 200-230 VAC | K8AB-VW3 200-230 VAC | 
            A shunt is a resistor to convert a DC current into a DC voltage.
Use the shunt in combination with K8AB-VW to detect undercurrent and overcurrent in DC circuits.
        
| Model | Rated current | Output voltage | 
|---|---|---|
| SDV-SH5 | 5 A | 60 mV | 
| SDV-SH7.5 | 7.5 A | |
| 7.5 A (for 100 mV) | 100 mV | |
| SDV-SH10 | 10 A | 60 mV | 
| SDV-SH15 | 15 A | |
| SDV-SH20 | 20 A | |
| SDV-SH30 | 30 A | |
| SDV-SH50 | 50 A | |
| SDV-SH75 | 75 A | |
| SDV-SH100 | 100 A | |
| SDV-SH150 | 150 A | |
| SDV-SH200 | 200 A | |
| SDV-SH300 | 300 A | |
| SDV-SH500 | 500 A | |
| SDV-SH750 | 750 A | |
| SDV-SH1000 | 1,000 A | 
       
    
| Phase-sequence Phase-loss Relay | Functions | Rated input voltage * | Model | 
|---|---|---|---|
										![]()  | 
									Phase sequence and
 phase loss monitoring  | 
									200 to 500 VAC | K8AB-PH1 | 
* The power supply is shared with the rated input voltage.
| Three-phase Phase-sequence Phase-loss Relay | Rated input (See note 2.) | Model | |
|---|---|---|---|
										 
										 | 
									3-phase 3-wire mode | 200, 220, 230, 240 VAC | K8AB-PM1 | 
| 3-phase 4-wire mode | 115, 127, 133, 138 VAC | ||
| 3-phase 3-wire mode | 380, 400, 415, 480 VAC | K8AB-PM2 | |
| 3-phase 4-wire mode | 220, 230, 240, 277 VAC | ||
| 
										Three-phase Asymmetry and Phase-sequence  Phase-loss Relay  | 
									Rated input (See note 2.) | Model | |
|---|---|---|---|
										 
										 | 
									3-phase 3-wire mode | AC 200, 220, 230, 240 | K8AB-PA1 | 
| 3-phase 4-wire mode | AC 115, 127, 133, 138 | ||
| 3-phase 3-wire mode | AC 380, 400, 415, 480 | K8AB-PA2 | |
| 3-phase 4-wire mode | AC 220, 230, 240, 277 | ||
| Three-phase Voltage Relay | Rated input (See note 2.) | Model | |
|---|---|---|---|
										 
										 | 
									3-phase 3-wire mode | 200, 220, 230, 240 VAC | K8AB-PW1 | 
| 3-phase 4-wire mode | 115, 127, 133, 138 VAC | ||
| 3-phase 3-wire mode | 380, 400, 415, 480 VAC | K8AB-PW2 | |
| 3-phase 4-wire mode | 220, 230, 240, 277 VAC | ||
| Size | Supply
 voltage  | 
									Type | Number of
 outputs  | 
									Input type | Setting unit
 (setting range)  | 
									Model | 
|---|---|---|---|---|---|---|
| K8AB-TH
 22.5 × 90 × 100 mm  | 
									100 to
 240 VAC  | 
									Temper-
 ature input  | 
									1 (relay) | Thermocouple/Pt100 | Unit: 1°C/°F (0 to 399°C/°F) | K8AB-TH11S | 
| Thermocouple | Unit: 10°C/°F (See note 1.) | K8AB-TH12S | ||||
| 24 VAC/
 VDC  | 
									Thermocouple/Pt100 | Unit: 1°C/°F (0 to 399°C/°F) | K8AB-TH11S | |||
| Thermocouple | Unit: 10°C/°F (See note 1.) | K8AB-TH12S | 
last update: October 11, 2012