Edge Controller SCC-1224A

Power Input

Power supply voltage* 120 VAC 50/60Hz (Terminals A1 and A2)
24 VAC 50/60Hz or 24 VDC (Terminals B1 and B2)
Operating voltage range -10% to +10% of rated power supply voltage
Power consumption (with sensors connected) 120 VAC: 3.8 VA max. 50 Hz, 3.5 VA max. 60 Hz
24 VAC: 1.2 VA max., 24 VDC: 1.5 W max.

* Select either Terminals A1 and A2 or Terminals B1 and B2 according to the power supply voltage applied. Never apply
  both voltages simultaneously.

Inputs

Sensor input SGE Safety Edge: A maximum of 5 edges can be connected in series.
Maximum wiring length: 25 m max.

Contacts

Safety output 230 VAC 3 A, 24 VDC 3 A (resistive load)
230 VAC 1 A (AC-15), 24 VDC 2 A (DC-13) (inductive load)
Auxiliary output 24 VAC/DC 2A (resistive load)

Characteristics

Startup time *1300 ms max.
Operating time (Open to closed) *2550 ms max.
Response time (Closed to open) *313 ms max.
Vibration resistanceMalfunction: 10 to 55 Hz, Sinus, 0.15 mm amplitude, 10 cycles
Shock resistanceMalfunction: 147 m/s2
DurabilityMechanical1,000,000 cycles min.
ElectricalAC-15: 800,000 cycles min. (230 VAC, 1A)
DC-13: 250,000 cycles min. (24 VDC, 2A)
Ambient operating temperature-20 to 55°C (-4 to 131°F) (with no icing or condensation)
Ambient operating humidity0% to 90%
Degree of protectionIP20
Material (Housing)Polyamide PA6.6, self-extinguishing according to UL 94-V2
Protection typeClass II (protective insulation)
Pollution degree2
Overvoltage category (IEC/EN 60664-1)III
Rated insulation voltage250 V
Rated impulse voltage resistance4 kV
Dielectric strength1.5 kVAC
Terminal tightening torque0.5 to 0.6 N• m
Weightapprox. 210 g (7.4 oz)
ConformityConforming to StandardsEN ISO 13856-2, EN ISO 13849-1: 2015, EN 61000-6-2, EN 61000-6-3,
ANSI/UL 508, CSA C22.2 No.14
PFHd6.5× 10-9 (Nop 17,520)
MTTFd195 years
DC99% (Nop 17,520)

*1. The startup time is the delay time from power-on to when the SCC-1224A Safety Mat/Edge Controller is ready to
     operate.
*2. The operating time is the time it takes for the safety output contacts to be closed after the sensor is deactivated and the
      manual reset input contacts are closed.
      The contact bounce time is not included.
*3. The response time is the time it takes for the safety output contacts to open after the sensor is activated. Contact
      bounce time is included.

Safety Edge

Model SGE-125 SGE-225 *5 SGE-245
SGE-245L
SGE-365
Material *1 TPE EPDM
Material hardness 65 Shore A 68 Shore A
Max. length of a single safety edge 6.1 m
Actuation distance *2 2.6 mm 3.9 mm 7.4 mm 5.2 mm
Actuation force *2 42 N 57 N 68 N 78 N
Maximum allowable load 500 N
Overtravel distance *2 (400 N) 9.5 mm 6.7 mm 18.3 mm 33.8 mm
Maximum operation angle 2 x 30° 2 x 45°
Inactive end region *3 20 mm 40 mm 20 mm
Connecting cable 2 conductors, 0.34 mm2, Allowable bending radius: R38mm
Cable Specifications
Type: PUR (Polyurethane) Round lead cable
External diameter: 3.5 dia.
Number of conductors: 2 conductors
Cross-section of conducto: 0.34 mm2
Insulator diameter: 1.2 dia.
Mechanical durability 10,000 operations min.
Ambient temperature During operation: -10 to 55°C (with no icing),
During storage: -25 to 75°C (with no icing)
Operating ambient humidity 0 to 90%RH
Degree of protection IP65
Unit weight *4 0.18 kg/m 0.51 kg/m 0.77 kg/m (SGE-245)
0.82 kg/m (SGE-245L)
1.10 kg/m

*1. TPE: Thermoplastic Elastomer
      EPDM: Ethylene Propylene Rubber
*2. Values of actuation distance and actuation force are characteristic values tested according to EN ISO 13856-2 using a
      test object of ϕ80 mm and actuating point C3 under a test temperature of 20°C and test speed v = 10 mm/s. Refer
      to “Characteristics” on Catalog for details.
*3. There is an inactive region (including an end cap) in both ends of the safety edge.
      2617_sp_2
*4. Values are for the unit weight of TPE or EPDM devices. The weight does not include the aluminum base, cables,
      or connectors.
*5. The SGE-225 can be used for finger protection.The actuation force is 20 N when the SGE-225 is used for finger
      protection.
      (Characteristic values tested according to EN ISO 13856-2 using a test object of ϕ20 mm and actuating point C3 under
      a test temperature of 20°C and test speed v = 10 mm/s)

Mechanical Force

Material TPE EPDM
Model SGE-125 SGE-225, SGE-245, SGE-365
Features Strength * 1 2 3 4 5 6 1 2 3 4 5 6
Tear Strength (Resistance) 3 3
Ultimate Tensile Strength 3 3
Rebound Elasticity at 20°C 2 2
Resistance Against Permanent Deformation 3 4 2
Abrasion 3 3
Elongation at Tear 4 5 3
Cold Flexibility 2 2

Note: 1 = Excellent
         2 = Very good
         3 = Good
         4 = Fair
         5 = Poor
         6 = Very poor

Environmental Resistance

Material TPE EPDM
Model SGE-125 SGE-225, SGE-245, SGE-365
Features Tolerance * 1 2 3 4 5 6 1 2 3 4 5 6
Heat Stability 4 2
Oxidation Stability 1 1
UV Stability 1 1
Weather/Ozone Resistance 1 1
Flame Resistance 6 6
Gas Permeability 3 4

Note: 1 = Excellent
         2 = Very good
         3 = Good
         4 = Fair
         5 = Poor
         6 = Very poor

Chemical Resistance

Material TPE EPDM
Model SGE-125 SGE-225, SGE-245, SGE-365
Features Effects * 1 2 3 4 5 6 1 2 3 4 5 6
Water Resistance 1 1 2
Diluted Acids 1 2
Diluted Bases 1 2
Non-Oxidizing Acids 2 2
Oxidizing Acids 2 4
ASTM Oil #3 2 6
Vegetable Oils 1 2 5
Organic Solvents 2
Ester Solvents 2 3 2
Ketone Solvents (Containing Oxygen) 2 3 3
Aliphatic Hydrocarbons Solvents (Gasoline) 5
Aromatic Hydrocarbons 6
Hydrocarbons 2 3 5 6
Alcohol 1 1

Note: 1 = No Effects, Permanent Contact
         2 = Few Effects, Some Contact
         3 = Medium Effects, Some Contact
         4 = Noticeable Effects, Reduced Contact
         5 = Severe Effects, Very Brief Contact
         6 = Extreme Effects, Avoid Contact