General-purpose Basic Switch
last update: September 24, 2012
Rated voltage | Non-inductive load (A) | Inductive load (A) | ||||||
---|---|---|---|---|---|---|---|---|
Resistive load | Lamp load | Inductive load | Motor load | |||||
NC | NO | NC | NO | NC | NO | NC | NO | |
8 VDC 14 VDC 30 VDC 125 VDC 250 VDC |
10 10 10 10 3 |
3 3 3 3 1.5 |
1.5 1.5 1.5 1.5 0.75 |
10 10 10 7.5 2 |
10 10 10 6 1.5 |
5 5 5 5 2 |
2.5 2.5 2.5 2.5 1.5 |
|
Contacts | Material | Silver |
---|---|---|
Gap (standard value) | 0.9 mm | |
Inrush current | NC | 30 A max. |
NO | 15 A max. |
Operating speed | 0.1 mm to 1 m/s *1 | |
---|---|---|
Operating frequency |
Mechanical | 240 operations/min |
Electrical | 20 operations/min | |
Insulation resistance | 100 M Ω min. (at 500 VDC) | |
Contact resistance | 15 m Ω max. (initial value) | |
Dielectric strength | 1,500 VAC, 50/60 Hz for 1 min between terminals of the same polarity, between current-carrying metal parts and the ground, and between each terminal and non-current-carrying metal parts | |
Vibration resistance |
Malfunction | 10 to 55 Hz, 1.5-mm double amplitude *2 |
Shock resistance |
Destruction | 1,000 m/s2 max. |
Malfunction | 300 m/s2 max. *1 *2 | |
Durability | Mechanical | 1,000,000 operations min. |
Electrical | 100,000 operations min. | |
Degree of protection | IP00 | |
Degree of protection against electric shock |
Class I | |
Proof tracking index (PTI) | 175 | |
Ambient operating temperature | − 25 ° C to 80 ° C (with no icing) | |
Ambient operating humidity | 35% to 85%RH | |
Weight | Approx. 27 to 63 g |
*1. The values are for the pin plunger models. (Contact your OMRON representative for other models.)
*2. Malfunction: 1 ms max.
last update: September 24, 2012