Small Sealed Switch
            
        
last update: September 1, 2025
| Agency | Standard | File No. | Approved models | 
|---|---|---|---|
| UL | UL508 | E76675 | D4E-[][]10N/D4E-[][]20N Switches only except
 for Indicator-equipped Switches  | 
| CSA | CSA C22.2 No. 14 | LR45746 | D4E-[][]20N Switches only except for Indicator-
 equipped Switches  | 
| TÜV Rheinland | EN60947-5-1 | R9551015 | Ask your OMRON representative for information on
 approved models.  | 
| CCC (CQC) | GB/T14048.5 | Contact your OMRON
 representative for details.  | 
Ask your OMRON representative for information on
 approved models.  | 
| Rated voltage | Standard load | Micro load | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Non-inductive load (A) | Inductive load (A) | Non-inductive load (A) | ||||||||
| Resistive load | Lamp load | Inductive load | Motor load | Resistive load | ||||||
| NC | NO | NC | NO | NC | NO | NC | NO | NC | NO | |
| 125 VAC
 250 VAC  | 
										5 (1)
 5 (1)  | 
										1.5 (1)
 1.5 (1)  | 
										3 (1)
 3 (1)  | 
										2 (1)
 1  | 
										1 (1)
 0.5  | 
										0.1
 ---  | 
									||||
| 8 VDC
 14 VDC 30 VDC 125 VDC 250 VDC  | 
										5 (1)
 5 (1) 5 (1) 0.5 0.25  | 
										---
 --- --- --- ---  | 
										1.5 (1)
 1.5 (1) 1.5 (1) 0.05 0.03  | 
										---
 --- --- --- ---  | 
										0.1
 0.1 0.1 --- ---  | 
									|||||
| Minimum applicable load | Standard load | Micro load | 
|---|---|---|
| 160 mA at 5 VDC | 1 mA at 5 VDC | 
| Inrush current | NC | 10 A max. | 
|---|---|---|
| NO | 10 A max. | 
| Voltage | Carry current | Current (A) | Volt-amperes (VA) | ||
|---|---|---|---|---|---|
| Make | Break | Make | Break | ||
| 120 V
 240 V  | 
									10 A | 60 A
 30 A  | 
									6 A
 3 A  | 
									7,200 | 720 | 
       
    
| Model | Applicable category and ratings | Thermal current
 (Ithe)  | 
									Indicator | |||
|---|---|---|---|---|---|---|
| I | II | III | IV | |||
| 1 | [] | 00 | AC-14 0.5 A/125 VAC | 5 A | --- | |
| 1 | [] | 10 | DC-12 0.5 A/30 VDC | 5 A | --- | |
| 1 | [] | 20, 21, 22 | AC-15 2A/250 VAC
 DC-12 2A/48 VDC  | 
									5 A | --- | |
| 1 | [] | 23, 24 | L | AC-15 2A/250 VAC | 5 A | Neon lamp | 
| 1 | [] | 23, 24 | L1 | DC-12 2A/12 VDC | 5 A | LED | 
| 1 | [] | 23, 24 | L2 | DC-12 2A/24 VDC | 5 A | LED | 
| 1 | [] | 23, 24 | L3 | DC-12 2A/48 VDC | 5 A | LED | 
| 2 | [] | 00 | AC-14 0.1A/125 VAC | 0.5 A | --- | |
| 2 | [] | 10 | DC-12 0.1A/30 VDC | 0.5 A | --- | |
| 2 | [] | 20, 21, 22 | AC-14 0.1A/125 VAC
 DC-12 0.1A/48 VDC  | 
									0.5 A | --- | |
| 2 | [] | 23, 24 | L | AC-14 0.1A/125 VAC | 0.5 A | Neon lamp | 
| 2 | [] | 23, 24 | L1 | DC-12 0.1A/12 VDC | 0.5 A | LED | 
| 2 | [] | 23, 24 | L2 | DC-12 0.1A/24 VDC | 0.5 A | LED | 
| 2 | [] | 23, 24 | L3 | DC-12 0.1A/48 VDC | 0.5 A | LED | 
| Degree of protection *2 | IP67 (EN60947-5-1) | |
|---|---|---|
| Durability *1 | Mechanical | 20,000,000 operations min. (10,000,000 operations min.
 for D4E-[]D/D4E-[]E/D4E-[]F/D4E-[]H)  | 
| Electrical | 500,000 operations min. (5 A at 250 VAC, resistive load)
 5,000,000 operations min. (10 mA at 24 VDC, resistive load)  | 
|
| Operating speed | 0.1 mm/sec to 0.5 m/sec | |
| Operating frequency | Mechanical: 120 operations/min
 Electrical: 30 operations/min  | 
|
| Rated frequency | 50/60 Hz | |
| Insulation resistance | 100 MΩ min. (at 500 VDC) | |
| Contact resistance | 15 mΩ max. (initial value for the built-in switch when tested alone) | |
| Dielectric strength | Between terminals of same
 polarity  | 
1,000 VAC, 50/60 Hz for 1 min | 
| Between each terminal and
 non-current-carrying metal part  | 
1,500 VAC, 50/60 Hz for 1 min/Uimp at 2.5 kV (EN60947-5-1) | |
| Rated insulation voltage (Ui) | 250V | |
| Pollution degree (operating environment) | 3 (EN60947-5-1) | |
| Short-circuit protective device (SCPD) | 10 A fuse (type gG or gI, IEC60269 approved) | |
| Conditional short-circuit current | 100 A (EN60947-5-1) | |
| Conventional enclosed thermal current (Ithe) | 5 A (EN60947-5-1) | |
| Protection against electric shock | Class II (grounding not required with double insulation) | |
| Vibration resistance | Malfunction | 10 to 55 Hz, 1.5-mm double amplitude | 
| Shock resistance | Destruction | 1,000 m/s2 max. | 
| Malfunction | 300 m/s2 max. | |
| Ambient operating temperature | -10°C to +80°C (with no icing) | |
| Ambient operating humidity | 35% to 95%RH | |
| Weight | Approx. 86 g (in case of roller plunger) | |
            Note: 1. The above values are initial values.
   2. The above ratings may vary depending on the model. Contact your OMRON representative for further details.
*1. Durability values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH.
*2. The degree of protection is tested using the method specified by the standard (EN60947-5-1).
  Confirm that sealing properties are sufficient for the operating conditions and environment beforehand.
        
last update: September 1, 2025