DNV Certification (Norwegian Marine Standards)

 

Programmable Controllers

Field Networks

Programmable Terminals

Reduced Wiring Devices

   

 

Programmable Controllers

 

Model

Location Class

Temperature

Humidity

Vibration

EMC

Enclosure

C200HW/C200HX/C200HG/C200HE

A

A

A

A

*3

CJ1/CJ2

A

B

A

A

*3

CP1

B

B

A

A*2

*3

CQM1H/CQM1

B

A

A

A

*3

CS1

B

B

A

A

*3

CVM1D /CV500/C500/C1000H

B*1

B*1

A

A

*3

 

*1. The C1000H-APS01, however, is "A."
*2. Install inside a metal enclosure.
*3. There are no enclosure requirements for OMRON products. Follow the DNV enclosure requirements specified separately for installation locations of the panel containing the product.


Note 1: The above table lists series names. Ask your OMRON representative for details on specific model numbers.
Note 2: Model certification has not been received for usage on the deck, in the bridge, or in locations subject to strong vibration.


Model certification for the DNV (Det Norske Veritas) was made according to the Environmental Test Specific for Instrument and Automation Equipment Standard for Certification No. 2.4.

 

Refer to the following table for the location classes.

 

Column I

Column II

Parameter

Location within main area

MAIN AREAS ON BOARD

Machinery spaces Control room, Accommodation Bridge Pump room, Holds, Rooms with no heating Open Deck

Temperature

Inside cubicles, desks, etc. with temperature rise of 5°C or more

B

B

B

D

D

All other locations

A

A

A

C

D

Humidity

Locations where special precautions are taken to avoid condensation

A

A

A

A

A

All other locations

B

B

B

B

B

Vibration

On machinery such as internal combustion engines, compressors, pumps, including piping on such machinery

B

---

---

B

B

Masts

---

---

---

---

C

All other locations

A

A

A

A

A

EMC

All locations within specified main

A

A

B

A

B

Enclosure

Submerged application

D

---

---

D

D

Below floor plates in engine room

C

---

--

---

---

All other locations

B

A

A

B

C

 

 

Field Networks

 

Model

Location Class

Temperature

Humidity

Vibration

EMC

Enclosure

GRT1 Series

B

B

A

A

*

CS1W-CRM21

CJ1W-CRM21

CRS1-RPT01

 

* There are no enclosure requirements for OMRON products. Follow the DNV enclosure requirements specified separately for installation locations of the panel containing the product.


Note 1: The above table lists series names. Ask your OMRON representative for details on specific model numbers.
Note 2: Model certification has not been received for usage on the deck, in the bridge, or in locations subject to strong vibration.

 

 

Programmable Terminals

 

Model

Location Class

Temperature

Humidity

Vibration

EMC

Enclosure

NS5/NS8/NS10/NS12

A

B

A

B

A

 

Note:

1. The above table lists series names. Ask your OMRON representative for details on specific model numbers.
2. Model certification has not been received for usage on the deck, in the bridge, or in locations subject to strong vibration.

 

Reduced Wiring Devices

 

Model

Location Class

Temperature

Humidity

Vibration

EMC

Enclosure

G71/G72C

B

B

A

A

*

 

* There are no enclosure requirements for OMRON products. Follow the DNV enclosure requirements specified separately for installation locations of the panel containing the product.

Note:

1. The above table lists series names. Ask your OMRON representative for details on specific model numbers.
2. Model certification has not been received for usage on the deck, in the bridge, or in locations subject to strong vibration.


The following DNV (Det Norske Veritas) rules apply: Environmental Test Specific for Instrument and Automation Equipment Standard for Certification No. 2.4.

 

Top