General-purpose Relays
             
        
last update: May 19, 2025
| Rated voltage | Rated current | Coil resistance | Must operate voltage | Must release voltage | Max. voltage | Power consumption | ||
|---|---|---|---|---|---|---|---|---|
| 50 Hz | 60 Hz | |||||||
| AC | 6 V | 443 mA | 385 mA | 3.1 Ω | 80% max. of rated voltage | 30% min. of rated voltage at 60 Hz 25% min. of rated voltage at 50 Hz | 110% of rated voltage | Approx. 2.3 VA at 60 Hz Approx. 2.7 VA at 50 Hz | 
| 12 V | 221 mA | 193 mA | 13.7 Ω | |||||
| 24 V | 110 mA | 96.3 mA | 48.4 Ω | |||||
| 100 V | 26.6 mA | 23.1 mA | 760 Ω | |||||
| 110 V | 24.2 mA | 21.0 mA | 932 Ω | |||||
| 200 V | 13.3 mA | 11.6 mA | 3,160 Ω | |||||
| 220 V | 12.1 mA | 10.5 mA | 3,550 Ω | |||||
| 230 V | 10.0 mA | 11.5 mA | 4,250 Ω | |||||
| 240 V | 11.0 mA | 9.6 mA | 4,480 Ω | |||||
| DC | 6 V | 224 mA | 26.7 Ω | 15% min. of rated voltage | Approx. 1.4 W | |||
| 12 V | 112 mA | 107 Ω | ||||||
| 24 V | 55.8 mA | 430 Ω | ||||||
| 48 V | 28.1 mA | 1,710 Ω | ||||||
| 100 V | 13.5 mA | 7,390 Ω | ||||||
| 110 V | 12.3 mA | 8,960 Ω | ||||||
| 125 V | 10.8 mA | 11,576 Ω | ||||||
| Load | Resistive load (cosφ = 1) | Inductive load (cosφ = 0.4) | |
|---|---|---|---|
| Contact mechanism | Single | ||
| Contact material | Ag alloy | ||
| Rated load | NO | 10 A, 250 VAC 10A, 30 VDC | 7 A, 250 VAC | 
| NC | 5 A, 250 VAC 5 A, 30 VDC | ||
| Rated carry current | 10 A | ||
| Max. switching voltage | 250 VAC, 250 VDC | ||
| Max. switching current | 10 A | ||
| Max. switching power | NO | 2,500 VAC 300 WDC | 1,750 VAC | 
| NC | 1,250 VAC 150 WDC | ||
| Contact resistance | 100 mΩ max. | 
|---|---|
| Operate time | AC: 20 ms max. DC: 30 ms max. | 
| Release time | 20 ms max. (40 ms max. for built-in Diode Relays) | 
| Max. operating frequency | Mechanical: 18,000 operations/h Electrical: 1,800 operations/h (under rated load) | 
| Insulation resistance | 100 MΩ min. (at 500 VDC) | 
| Dielectric strength | 2,500 VAC 50/60 Hz for 1 min between coil and contacts 1,000 VAC 50/60 Hz for 1 min between contacts of same polarity and terminals of the same polarity 2,500 VAC 50/60 Hz for 1 min between current-carrying parts, non-current-carrying parts, and opposite polarity | 
| Insulation method | Basic insulation | 
| Impulse withstand voltage | 4.5 kV between coil and contacts (with 1.2 × 50 μs impulse wave) 3.0 kV between contacts of different polarity (with 1.2 × 50 μs impulse wave) | 
| Pollution degree | 3 | 
| Rated insulation voltage | 250 V | 
| Vibration resistance | Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Malfunction: 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude) | 
| Shock resistance | Destruction: 1,000 m/s2 (approx. 100 G) Malfunction: 100 m/s2 (approx. 10 G) | 
| Endurance | Mechanical: 5,000,000 operations min. (at 18,000 operations/h under rated load) Electrical: 100,000 operations h. (at 1,800 operations/h under rated load) | 
| Failure rate P level (reference value) | 10 mA at 1 VDC | 
| Ambient temperature | Operating: -40 to 60°C (with no icing or condensation) | 
| Ambient humidity | Operating: 5% to 85% | 
| Weight | Approx. 90 g | 
 
       
    
| Coil ratings | Contact ratings | Operations | |
|---|---|---|---|
| 6 to 110 VDC 6 to 240 VAC | N.O. contact | 10 A, 250 V AC 50/60 Hz (Resistive) 10 A, 30 V DC (Resistive) 7 A, 250 V AC 50/60 Hz (General Use) | 100,000 | 
| N.C. contact | 10 A, 250 V AC 50/60 Hz (Resistive) 10 A, 30 V DC (Resistive) 7 A, 250 V AC 50/60 Hz (General Use) | 100,000 | |
 
       
    
| Coil ratings | Number of Poles | Contact ratings | Operations | 
|---|---|---|---|
| 6 to 125 VDC 6 to 240 VAC | 2 | 10 A, 250 V AC (Resistive) 10 A, 30 V DC (Resistive) 7 A, 250 V AC (General Use) | 100,000 | 
| 3 | 10 A, 250 V AC (Resistive) Same Polarity 10 A, 30 V DC (Resistive) Same Polarity 7 A, 250 V AC (General Use) Same Polarity | 100,000 | 
 
       
    
| Coil ratings | Contact ratings | Operations | |
|---|---|---|---|
| 6, 12, 24, 48, 100, 110 VDC 6, 12, 24, 100, 110, 200, 220, 240 VAC | N.O. contact | 10 A, 250 V AC 50/60 Hz (Resistive) 10 A, 30 V DC (Resistive) 7 A, 250 V AC 50/60 Hz (General Use) | 100,000 | 
| N.C. contact | 5 A, 250 V AC 50/60 Hz (Resistive) 5 A, 30 V DC (Resistive) 7 A, 250 V AC 50/60 Hz (General Use) | 100,000 | |
Note: When Relays are mounted on the PF083A-E or PF113A-E, the maximum carrying current is 9 A.
last update: May 19, 2025