Uninterruptible Power Supply (UPS)
last update: September 1, 2025
| Capacity | 120 W | 240 W | 360 W | 480 W *4 | ||
|---|---|---|---|---|---|---|
| DC input | Rated input voltage | 24 VDC | ||||
| Input
voltage range |
When standard
voltage sensitivity is set |
24 VDC±10% | ||||
| When low voltage
sensitivity is set |
24 VDC±12.5% | |||||
| When high voltage
sensitivity is set |
24 VDC±5% | |||||
| Input
maximum current |
for rated input
voltage for rated loads connected |
5.9 A | 11.7 A | 17.5 A | 23.3 A *5 | |
| Input terminal | Push-in terminal block | |||||
| Input protection | Fuse (cannot be replaced by the customer) | |||||
| Input protection capacity | 10 A | 15 A | 30 A | |||
| DC output | Rated
current |
(for rated output
voltage) |
5 A | 10 A | 15 A | 20 A *6 |
| Switching time | Uninterrupted | |||||
| Output
voltage |
Normal operation | Output of input voltage as-is | ||||
| Backup operation | 24 V±5% | |||||
| Output terminal | Push-in terminal block | |||||
| Overload protection | Alarm display at a load level of 110% or over (normal operation) | |||||
| Alarm display at a load level of 110% or over and output voltage drop
(backup operation) |
||||||
| Alarm display cancellation at a load equal to or below the rated
capacity (normal operation, backup operation) |
||||||
| Battery | Type | Lithium-ion battery | ||||
| Rated voltage | 14.4 VDC | |||||
| Rated capacity | 1600 mAh ×
1 parallel |
1600 mAh ×
2 parallel |
1600 mAh ×
3 parallel |
1600 mAh ×
4 parallel |
||
| Expected battery life *1 | 2.5 years (50°C), 5 years (40°C), 10 years (25°C) | |||||
| Replacement by user | Yes (Hot swapping) | |||||
| Auto battery check function | Yes | |||||
| Battery life counter function | Yes | |||||
| Charging time | 4 hours *7 | |||||
| Backup time (25°C, initial characteristics) | 6 min. (120 W) | 6 min. (240 W) | 6 min. (360 W) | 6 min. (480 W) | ||
| Environment | Operating ambient
temperature/humidity |
0 to +55°C/10 to 90% (with no condensation) | ||||
| Storage ambient
temperature/humidity |
-20°to +55°C/10 to 90% (with no condensation) | |||||
| Vibration resistance | JIS C 60068-2-6 compliant. 5 to 8.4 Hz amplitude: 3.5 mm, 8.4 to 150
Hz acceleration rate: 9.8 m/s2 X, Y, and Z directions for 100 minutes (Time coefficient: 10 minutes × coefficient factor 10 = total time 100 min.) |
|||||
| Shock resistance | JIS C 60068-2-27 compliant. 147 m/s2, 3 times in X, Y, and Z
directions. |
|||||
| Structure | Dimensions (W × D × H mm) | 94 × 100 ×
100 |
148 × 100 ×
100 |
270 × 100 × 100 | ||
| Weight of unit | Approx. 0.8 kg | Approx. 1.3 kg | Approx. 2.0 kg | Approx. 2.3 kg | ||
| Cooling method | Natural cooling | |||||
| Insulation
and withstand voltage |
Withstand voltage | 1,000 V 50/60 Hz AC between the DC external terminals and the GR
terminal for 1 minute at a leakage current of 10 mA max. |
||||
| Insulation resistance | 20 MΩ min. between the DC external terminals and the GR terminal
(at 500 VDC) |
|||||
| Compliance
to standard |
Safety standard | UL508/CE/UKCA/C22.2 No.107.1-01 | ||||
| EMI | Radiated
disturbance electromagnetic field strength |
EN61000-6-4/FCC/ICES/RCM/KC | ||||
| Ship standard | LR/DNV/EN60945 *8 | |||||
| Internal power consumption (normal *2/
maximum *3) |
7 W/22 W | 11 W/41 W | 14 W/60 W | 18 W/80 W | ||
| Serial com-
munication |
RS-232C (Interface terminal) | Yes (RJ45) | ||||
| USB (interface terminal) | Yes (B connector) | |||||
| I/O signal (Interface terminal) | Yes (RJ45) | |||||
| Accessories | USB cable (1.5 m) | |||||
| Accessory functions | Beeper setting; Auto restart setting; Auto test setting; Auto restart
mode setting; Input sensitivity setting; Remote ON/OFF signal logic setting; Cold start setting; Battery life counter setting; Power switch function setting; Maximum backup time setting; Startup battery level setting; Backup stop (BS) signal delay time setting; Backup (BU) signal delay time setting; and Contact signal I/O test |
|||||
| Capacity | 480 W | 960 W | ||
|---|---|---|---|---|
| DC input | Rated input voltage | 24 VDC | ||
| Input voltage range | 23 to 28 VDC | |||
| Input
maximum current |
for rated input voltage
for rated loads connected |
21.5 A | 43.5 A | |
| Input terminal | Push-in terminal block | |||
| Input protection | Fuse (cannot be replaced by the customer) | |||
| Input protection capacity | 30 A | 60 A | ||
| DC output | Rated
current |
for rated output voltage | 20 A | 40 A |
| Switching time | Uninterrupted | |||
| Output
voltage |
Normal operation | Input voltage through output | ||
| Backup operation | 21 to 28 V (the voltage cannot be adjusted) | |||
| Output terminal | Push-in terminal block | |||
| Overload
protection |
Warning display
• UPS output will continue through bypass [during normal operation] • UPS output will continue through battery [during backup operation] |
101% or more | ||
| Output stopped by
overload protection • Stop output [during normal operation] • The internal power supply to the UPS will stop after 10 sec. [during backup operation] |
111% or more | |||
| Warning display
cancellation (During normal operation, during backup operation) |
93% or more | |||
| Battery unit | Type | Lithium-ion battery | ||
| Rated voltage | 25.2 VDC | |||
| Rated capacity | 3900 mAh | 7800 mAh | ||
| Battery life expectancy *1 | 10 years (25°C), 6.7 years (35°C), 3.7 years (45°C),
1.9 years (55°C) |
|||
| Replacement by user | Yes (Hot swapping) | |||
| Battery Life Counter Function | Yes | |||
| Charging time | 8 hours (90%) *3 | |||
| Backup time (25°C, initial
characteristics) |
6 min. (constant power rated load)
The backup time can be set from the mode selection/ backup operation time selection switch, or the shutdown software. |
|||
| Environment | Operating environment temperature/
humidity |
0 to +55°C / 10 to 90%RH with no condensation | ||
| Storage environment temperature/
humidity |
-20 to +55°C / 10 to 90%RH with no condensation | |||
| Vibration resistance | JIS C 60068-2-6 compliant
5 to 8.4 Hz amplitude: 3.5 mm, 8.4 to 150 Hz acceleration rate: 9.8 m/s2 X, Y, and Z directions: 100 min. (Sweep time: 10 min.×Sweep count 10 times=Total: 100 min.) |
|||
| Shock resistance | JIS C 60068-2-27 compliant: 147 m/s2 X, Y, and Z
directions three times |
|||
| Structure | Dimensions (W×H×D mm) *2 | 44 × 124 × 111.4 (UPS
control unit 20 A) 80 × 124 × 111.4 (battery unit 20 A) |
52 × 124 × 111.4 (UPS
control unit 40 A) 150 × 124 × 111.4 (battery unit 40 A) |
|
| Weight | Weight of control unit | Approx. 0.6 kg | Approx. 0.7 kg | |
| Weight of battery unit | Approx. 1.5 kg | Approx. 2.5 kg | ||
| Cooling method | Natural cooling | |||
| Dielectric
breakdown voltage |
Withstand voltage | DC external terminals to casing: 510 V AC, 1 minute,
leakage current 5 mA max. |
||
| Insulation resistance | DC external terminals to casing: 20 MΩ or more. (500 V
DC) |
|||
| Standard
compliance |
Safety standard | UL508/CE/UKCA/C22.2 No. 107.1-01 | ||
| EMI | Radiation disturbance
field strength |
EN61000-6-4/FCC/ICES/RCM/KC | ||
| Internal power consumption
(normal *4/maximum *5) |
7 W/29 W | 15 W/58 W | ||
| Serial com-
munication |
RS-232C (Interface terminal) | Yes (RJ45) | ||
| USB (Interface terminal) | ||||
| I/O signal (Interface terminal) | Yes (RJ45) | |||
| Accessories | USB cable (2.2 m) (included with control unit)
Battery communication cable (included with battery unit) |
|||
| Accessory functions | Remote ON/OFF signal logic setting; Battery life counter
setting; Maximum backup time setting; Startup battery level setting; Backup stop (BS) signal delay time setting; and Backup (BU) signal delay time setting |
|||
last update: September 1, 2025